Simply OPTURA®

Real-Time Biomass Monitoring
Doesn’t Have to Be Complicated

Bioprocess monitoring often relies on a “wait and see” approach. You take a sample, head to the lab, and wait for results while the culture continues to grow. When teams consider switching to real-time monitoring, there can be hesitation – the fear of complex installations, invasive retrofitting, or steep learning curves.

  • Modify your existing setup: Change the physical configuration of the vessel, assigning a port for an insertion sensor
  • Re-validate: Weeks can be spent re-qualifying equipment after a hardware change. OPTURA SPY® integrates without altering your existing validated footprint, keeping your focus on the cells, not on paperwork.

Since the OPTURA SPY® is non-invasive, it ignores those traditional hurdles. It means you don’t have to change your existing process to get the data you need. You just add the sensor to the process you already have and start seeing results immediately, see the setup process here.

  • Reducing “Downtime”: You don’t have to wait for the next “clean” cycle or a scheduled maintenance window to install it. You can attach the sensor via its single-use stick-on vessel adaptor and start measuring biomass straight away.
  • No Contamination Risk: Because it doesn’t touch the media, you don’t have to worry about the sensor introducing contamination to the batch.
  • Fixed NIR Wavelength: Some optical biomass monitoring methods require you to select a wavelength that is optimised for your cell type. The OPTURA SPY® has a fixed NIR wavelength that acts as a ‘one size fits all’ that works with various cell types.
  • Simplified Calibration and Verification: The OPTURA SPY® streamlines setup and removes recurring costs:
    • Pre-Calibrated: Pre-calibrated at ABER Instruments, the OPTURA SPY® only requires quick verification upon installation—no full calibration is needed. This removes setup time and eliminates the recurring cost and hassle of extra reagents and consumables.
    • Immediate Start: Users can also start measuring with OPTURA® without pre-calibration. Just stick it on the vessel, start monitoring and retrospectively add a biomass calibration so that next time, it will read out in your preferred biomass measurement. Read more on that here.
The Old Way (Manual Sampling)The Optura Way (Real-Time)
Intermittent data points (gaps in knowledge)Continuous data stream (the full picture)
Risk of contamination through samplingZero risk (non-invasive measurement)
Labor intensive (manual prep and analysis)Automated (set it and forget it)

“Simple” doesn’t just apply to the hardware; it applies to the output. OPTURA SPY® provides a clean, real-time signal of biomass concentration that can be viewed in the complimentary data visualisation software, OpturaView or it integrates directly into your existing control software.

FAQs

Does the OpturaSPY need to be sterilized?

Does the OpturaSPY require a specific wavelength?

The Optura SPY utilises a fixed NIR wavelength of 1330nm, this wavelength is chosen for multiple reasons including; it’s penetration depth is only 2.5cm so it does not need much room to measure, coloured media does not impact the measurement return and its sensitivity towards biomass whatever the cell type (Bacteria, Yeast, Mammalian cells etc.)

Is pre-calibration required to start using OpturaSPY?

Optura SPY does not require any system calibrations. The system is calibrated in-house at ABER by our experienced manufacturing team. When using the system, there are no calibrations apart from verifying that the measurements are in-line with expectations using a verification procedure. The only calibration you need to do is if you would like the Optura SPY to read out in your preferred biomass measurement (eg: cells/ml, g/l etc.)

Can Optura SPY be used on Single Use Bags?

What cell types can be monitored with the OPTURA SPY?

What is the difference between OpturaPALM and OpturaSPY?